高级检索
当前位置: 首页 > 详情页

The relationship between choroidal thickness and axis length and corneal curvature in high myopia

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ophthalmology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, P.R. China
出处:
ISSN:

关键词: Spectral-domain optical coherence tomography Depth enhanced imaging technology Choroidal thickness Axial length

摘要:
Objectives: To measure choroidal thickness (CT) in highly myopia eyes using enhanced depth imaging spectral-domain optical tomography (EDI SD-OCT) and explore the relationship between the CT and axial length (AL) and corneal curvature. Methods: This study assessed 66 eyes of 33 patients with both eyes of high myopia (equivalent sphericity >=-6D or AL >= 26mm) who underwent treatment at the department of ophthalmology, fourth hospital of Hebei Medical University from August 2020 to August 2021(High-myopia group). The control group included 54 eyes from 27 healthy volunteers. The patients in the two groups were 18 similar to 40 years old. EDI SD-OCT was used to measure the CT of subfoveal choroidal thickness (SFCT) and CT from fovea to nasal and temporal sides at an interval of 500 similar to 2500 mu m. The intraocular pressure, diopter, ocular axis, corneal curvature, and CT were compared between the two groups. The correlation between CT, diopter and AL was measured by Pearson's r. Results: The diopter, AL, vertical corneal curvature, and CT in the high-myopia group were significantly higher than those in the control group (P<0.05). There was significant correlation between SFCT and AL in both groups (P<0.05). There was a negative correlation between AL and CT in high-myopia group (r=-0.395, P<0.05), and a positive correlation between AL and CT in control group (r=0.29, P<0.05). There was a weak correlation between AL and gender, intraocular pressure, and horizontal corneal curvature(P<0.05), and a negative correlation between AL and diopter (r=-0.861, P<0.001). Conclusion: EDI SD-OCT can quantitatively measure the CT of high myopia. The CT of patients with high myopia was significantly thinner than that of the control group of the same age. There was a significant correlation between diopter, AL and CT, suggesting that AL is a parameter indicating the degree of myopia, and the change of CT may play a role in the occurrence and development of high myopia.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2022]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Ophthalmology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, P.R. China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39804 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号