Real-time 3D MRI reconstruction from cine-MRI using unsupervised network in MRI-guided radiotherapy for liver cancer

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China. [2]National Cancer Center/National Clinical Research Center for Cancer/Hebei Cancer Hospital, Chinese Academy of Medical Sciences, Langfang, 065001, China.
出处:
ISSN:

摘要:
Respiration has a major impact on the accuracy of radiation treatment for thorax and abdominal tumors. Instantaneous volumetric imaging could provide precise knowledge of tumor and normal organs' three-dimensional (3D) movement, which is the key to reducing the negative effect of breathing motion. Therefore, this study proposed a real-time 3D MRI reconstruction method from cine-MRI using an unsupervised network.Cine-MRI and setup 3D-MRI from eight patients with liver cancer were utilized to establish and validate the deep learning network for 3D-MRI reconstruction. Unlike previous methods that required 4D-MRI for network training, the proposed method utilized a reference 3D-MRI and cine-MRI to generate the training data. Then, a network was trained in an unsupervised manner to estimate the relationship between the cine-MRI acquired on coronal plane and deformation vector field (DVF) that describes the patient's breathing motion. After the training process, the coronal cine-MRI were inputted into the network, and the corresponding DVF was obtained. By wrapping the reference 3D-MRI with the generated DVF, the 3D-MRI could be reconstructed.The reconstructed 3D-MRI slices were compared with the corresponding phase-sorted cine-MRI using dice similarity coefficients (DSCs) of liver contours and blood vessel localization error. In all patients, the liver DSC had mean value >96.1% and standard deviation <1.3%; the blood vessel localization error had mean value < 2.6 mm, and standard deviation was <2.0 mm. Moreover, the time for 3D-MRI reconstruction was approximately 100 ms. These results indicated that the proposed method could accurately reconstruct the 3D-MRI in real time.The proposed method could accurately reconstruct the 3D-MRI from cine-MRI in real time. This method has great potential in improving the accuracy of radiotherapy for moving tumors. This article is protected by copyright. All rights reserved.This article is protected by copyright. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版] 出版后一年[2024版]

第一作者:
第一作者机构: [1]National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China. [2]National Cancer Center/National Clinical Research Center for Cancer/Hebei Cancer Hospital, Chinese Academy of Medical Sciences, Langfang, 065001, China.
通讯作者:
通讯机构: [1]National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China. [*1]Department of Radiation Oncology National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College Beijing 100021, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号