高级检索
当前位置: 首页 > 详情页

Combining distance and anatomical information for deep-learning based dose distribution predictions for nasopharyngeal cancer radiotherapy planning

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc, Beijing, Peoples R China [2]Chinese Acad Med Sci, Hebei Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc, Langfang, Peoples R China
出处:
ISSN:

关键词: dose-prediction minimum distance anatomical information deep-learning radiotherapy treatment planning

摘要:
PurposeDeep-learning effectively predicts dose distributions in knowledge-based radiotherapy planning. Using anatomical information that includes a structure map and computed tomography (CT) data as input has been proven to work well. The minimum distance from each voxel in normal structures to planning target volume (DPTV) closely affects each voxel's dose. In this study, we combined DPTV and anatomical information as input for a deep-learning-based dose-prediction network to improve performance. Materials and methodsOne hundred patients who underwent volumetric-modulated arc therapy for nasopharyngeal cancer were selected in this study. The prediction model based on a residual network had DPTV maps, structure maps, and CT as inputs and the corresponding dose distribution maps as outputs. The performances of the combined distance and anatomical information (COM) model and the traditional anatomical (ANAT) model with two-channel inputs (structure maps and CT) were compared. A 10-fold cross validation was performed to separately train and test the COM and ANAT models. The voxel-based mean error (ME), mean absolute error (MAE), dosimetric parameters, and dice similarity coefficient (DSC) of isodose volumes were used for modeling evaluation. ResultsThe mean MAE of the body volume of the COM model were 4.89 +/- 1.35%, highly significantly lower than those for the ANAT model of 5.07 +/- 1.37% (p<0.001). The ME values of the body for the 2-type models were similar (p >0.05). The mean DSC values of the isodose volumes in the range of 60 Gy were all better in the COM model (p<0.05), and there were highly significant differences between 10 Gy and 55 Gy (p<0.001). For most organs at risk, the ME, MAE, and dosimetric parameters predicted by both models were concurrent with the ground truth values except the MAE values of the pituitary and optic chiasm in the ANAT model and the average mean dose of the right parotid in the ANAT model. ConclusionsThe COM model outperformed the ANAT model and could improve automated planning with statistically highly significant differences.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 肿瘤学
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 肿瘤学
JCR分区:
出版当年[2023]版:
Q2 ONCOLOGY
最新[2023]版:
Q2 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc, Beijing, Peoples R China [2]Chinese Acad Med Sci, Hebei Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc, Langfang, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39770 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号