高级检索
当前位置: 首页 > 详情页

Prediction of lymphovascular invasion in esophageal squamous cell carcinoma by computed tomography-based radiomics analysis: 2D or 3D?

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Med Univ, Hosp 4, Dept Computed Tomog & Magnet Resonance Imaging, Shijiazhuang 050011, Hebei, Peoples R China [2]Hebei Med Univ, Hosp 4, Dept Radiotherapy, Shijiazhuang, Hebei, Peoples R China [3]Hebei Med Univ, Hosp 4, Dept Pathol, Shijiazhuang, Hebei, Peoples R China [4]Hebei Med Univ, Hosp 4, Dept Thorac Surg, Shijiazhuang, Hebei, Peoples R China [5]Hebei Childrens Hosp, Dept Radiol, Shijiazhuang, Hebei, Peoples R China [6]GE Healthcare China, Beijing, Peoples R China
出处:
ISSN:

关键词: Esophageal squamous cell carcinoma Radiomics Computed tomography Lymphovascular invasion

摘要:
BackgroundTo compare the performance between one-slice two-dimensional (2D) and whole-volume three-dimensional (3D) computed tomography (CT)-based radiomics models in the prediction of lymphovascular invasion (LVI) status in esophageal squamous cell carcinoma (ESCC).MethodsTwo hundred twenty-four patients with ESCC (158 LVI-absent and 66 LVI-present) were enrolled in this retrospective study. The enrolled patients were randomly split into the training and testing sets with a 7:3 ratio. The 2D and 3D radiomics features were derived from the primary tumors' 2D and 3D regions of interest (ROIs) using 1.0 mm thickness contrast-enhanced CT (CECT) images. The 2D and 3D radiomics features were screened using inter-/intra-class correlation coefficient (ICC) analysis, Wilcoxon rank-sum test, Spearman correlation test, and the least absolute shrinkage and selection operator, and the radiomics models were built by multivariate logistic stepwise regression. The performance of 2D and 3D radiomics models was assessed by the area under the receiver operating characteristic (ROC) curve. The actual clinical utility of the 2D and 3D radiomics models was evaluated by decision curve analysis (DCA).ResultsThere were 753 radiomics features from 2D ROIs and 1130 radiomics features from 3D ROIs, and finally, 7 features were retained to construct 2D and 3D radiomics models, respectively. ROC analysis revealed that in both the training and testing sets, the 3D radiomics model exhibited higher AUC values than the 2D radiomics model (0.930 versus 0.852 and 0.897 versus 0.851, respectively). The 3D radiomics model showed higher accuracy than the 2D radiomics model in the training and testing sets (0.899 versus 0.728 and 0.788 versus 0.758, respectively). In addition, the 3D radiomics model has higher specificity and positive predictive value, while the 2D radiomics model has higher sensitivity and negative predictive value. The DCA indicated that the 3D radiomics model provided higher actual clinical utility regarding overall net benefit than the 2D radiomics model.ConclusionsBoth 2D and 3D radiomics features can be employed as potential biomarkers to predict the LVI in ESCC. The performance of the 3D radiomics model is better than that of the 2D radiomics model for the prediction of the LVI in ESCC.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2025]版:
大类 | 2 区 医学
小类 | 2 区 肿瘤学 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 肿瘤学 2 区 核医学
JCR分区:
出版当年[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ONCOLOGY
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ONCOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2024版] 出版当年五年平均 出版前一年[2023版]

第一作者:
第一作者机构: [1]Hebei Med Univ, Hosp 4, Dept Computed Tomog & Magnet Resonance Imaging, Shijiazhuang 050011, Hebei, Peoples R China
通讯作者:
通讯机构: [1]Hebei Med Univ, Hosp 4, Dept Computed Tomog & Magnet Resonance Imaging, Shijiazhuang 050011, Hebei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号