Breast non-mass enhancement lesions on contrast-enhanced mammography: modified breast image reporting and data system classification

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology and Nuclear Medicine Department, The First Hospital of Hebei Medical University, Shijiazhuang, China [2]Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China [3]Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, China
出处:
ISSN:

摘要:
AIM: To investigate the utility of contrast-enhanced mammography (CEM) in the differential diagnosis of breast non-mass enhancement (NME) lesions, and to compare the diagnostic performance of BI-RADS for NME lesions in MG, US, MRI, and CEM. MATERIALS AND METHODS: A total of 120 patients were included from April 2019 to April 2022. The independent enhancement descriptors for malignancy of NME were identified through binary logistic regression analysis. The modified BI-RADS in CEM (mBI-RADS (CEM)) was defined after adjusting the BI-RADS (MG) by independent descriptors. The diagnostic performances of BI-RADS in low-energy image, US, MRI, and CEM were evaluated and compared using receiver operating characteristic (ROC) analysis and DeLong's test. RESULTS: The enhancement descriptors of enhancement morphological distribution, internal enhancement pattern and time-signal intensity curve were identified as independent risk factors for malignancy (all P<0.001). For all-group NME analyses, the areas under the curve (AUCs) of mBI-RADS (CEM) were higher than those of BI-RADS (MG) (all P<0.050). For subgroup NME analyses, the AUCs of mBI-RADS (CEM) and BI-RADS (MRI) were higher than those of BI-RADS (MG) and BI-RADS (US) (all P<0.001). While in NME with nonemicrocalcification sub-group, the area under the receiver operating characteristics curve of mBIRADS (CEM) was higher than those of BI-RADS (MRI), both of which were higher than those of BI-RADS (MG) and BI-RADS (US) (all P<0.050). CONCLUSION: The mBI-RADS (CEM), which integrates morphological and enhancement features, can significantly improve the diagnostic accuracy compared with BI-RADS (MG). Furthermore, the mBI-RADS (CEM) demonstrated specific advantages for NME with microcalcifications compared with BI-RADS (MRI). (c) 2025 The Royal College of Radiologists. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.

语种:
WOS:
PubmedID:
中科院分区:
出版当年[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2024]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2025版] 出版当年五年平均 出版前一年[2024版]

第一作者:
第一作者机构: [1]Department of Radiology and Nuclear Medicine Department, The First Hospital of Hebei Medical University, Shijiazhuang, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42313 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号