高级检索
当前位置: 首页 > 详情页

Precision dose measurement of I-125 seed in solid water through SPECT/CT detecting

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, The 4th Affiliated Hospital of Hebei Medical University, [2]Department of Oncology, Hebei General Hospital, Shijiazhuang, [3]Department of Bioengineering, Imperial College London, South Kensington, London, United Kingdom [4]Department of Nuclear Medicine, Tangshan People’s Hospital Medical Group, Tangshan, China
出处:
ISSN:

关键词: I-125 seed brachytherapy dose radioactive count value single-photon emission computed tomography

摘要:
Purpose: The aim of the study is to study the feasibility of gamma-ray-detection-based precision dose measurement of I-125 seed brachytherapy in solid water. Materials and Methods: Seven group I-125 seeds with different activities were put into a hole in the center of solid water individually. Each group had ten seeds, and the seed activity ranged from 1.48 x 10(7) Bq to 3.7 x 10(7) Bq. Single-photon emission computed tomography/computed tomography (SPECT/CT) was used to scan the seeds perpendicular to the long axis of the seed, with a slice thickness of 3.75 mm. The radioactive count values (x) of the radioactive concentration around the seeds were collected at a distance of 1u15 mm from the center of the seeds, while the corresponding doses (Y) (Gy) were calculated. SPSS 18.0 was used to analyze the relationship between the count value and the dose. Results: With the same seed activity, the count values became smaller according to the distance from the center of the seeds. The count values at the same point had an increasing trend according to the activity. This is similar to the doses calculated at the same point. There was an exponential relationship between the dose around the I-125 seeds, and the radioactive count value detected by SPECT/CT. Correlative curves between the dose and radioactive count value detected by SPECT/CT of different-activity I-125 seeds were fitted. The formulas of the dose and radioactive count with different seed activity were in the form of Y = b0 (b1)(x). The constant b0 ranged from 1.48 to 3.93, according to the seed activity, while b1 was 1.006 for every seed's activity. Conclusion: The count value around the I-125 seed can be detected accurately by SPECT/CT, and then can be quantified. This study provided useful experiment data for the precision measurement of I-125 seed implantation. Radiation detection-based dose measurement may become a new noninvasive technology for the dynamic dosimetry verification method after brachytherapy.

语种:
WOS:
PubmedID:
中科院分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
JCR分区:
出版当年[2019]版:
Q4 ONCOLOGY
最新[2024]版:
Q4 ONCOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Radiology, The 4th Affiliated Hospital of Hebei Medical University, [2]Department of Oncology, Hebei General Hospital, Shijiazhuang,
通讯作者:
通讯机构: [1]Department of Radiology, The 4th Affiliated Hospital of Hebei Medical University, [*1]Department of Radiology, The 4th Affiliated Hospital of Hebei Medical University, Shijiazhuang, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42313 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号