Objective: To investigate the use of non-linear-blending and monochromatic dual-energy CT (DECT) images to improve the image quality of hepatic venography. Methods: 82 patients undergoing abdominal DECT in the portal venous phase were enrolled. For each patient, 31 data sets of monochromatic images and 7 data sets of non-linear-blending images were generated. The data sets of the non-linear-blending andmonochromatic images with the best contrast-to-noise ratios (CNRs) for hepatic veins were selected and compared with the images obtained at 80kVp and a simulated 120 kVp. The subjective image quality of the hepatic veins was evaluated using a fourpoint scale. The image quality of the hepatic veins was analysed using signal-to-noise ratio (SNR) and CNR values. Results: The optimal CNR between hepatic veins and the liver was obtained with the non-linear-blending images. Compared with the other three groups, there were significant differences in the maximum CNR, the SNR, the subjective ratings and the minimum background noise (p < 0.001). A comparison of the monochromatic and 80-kVp images revealed that the CNR and subjective ratings were both improved (p < 0.001). There was no significant difference in the CNR or subjective ratings between the simulated 120-kVp group and the control group (p = 0.090 and 0.053, respectively). Conclusion: The non-linear-blending technique for acquiring DECT provided the best image quality for hepatic venography. Advances in knowledge: DECT can enhance the contrast of hepatic veins and the liver, potentially allowing the wider use of low-dose contrast agents for CT examination of the liver.
第一作者机构:[1]Department of Radiology, the Fourth Clinical Hospital of Hebei Medical University, Shijiazhuang, China
通讯作者:
推荐引用方式(GB/T 7714):
Wang Q.,Gaofeng S.,Xueli F.,et al.Comparative study of hepatic venography using non-linear-blending images, monochromatic images and low-voltage images of dual-energy CT[J].BRITISH JOURNAL OF RADIOLOGY.2014,87(1042):doi:10.1259/bjr.20140220.
APA:
Wang, Q.,Gaofeng, S.,Xueli, F.,Lijia, W.&Runze, W..(2014).Comparative study of hepatic venography using non-linear-blending images, monochromatic images and low-voltage images of dual-energy CT.BRITISH JOURNAL OF RADIOLOGY,87,(1042)
MLA:
Wang, Q.,et al."Comparative study of hepatic venography using non-linear-blending images, monochromatic images and low-voltage images of dual-energy CT".BRITISH JOURNAL OF RADIOLOGY 87..1042(2014)