The value of acoustic radiation force impulse (ARFI) in the differential diagnosis of thyroid nodules

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Ultrasound Department, The Fourth Hospital of Hebei Medical University, No.12 Jiankang Road, Shijiazhuang 050011, China
出处:
ISSN:

关键词: Thyroid nodules Acoustic radiation force impulse Virtual touch tissue quantification Ultrasound

摘要:
Objectives: The aim of this study was to investigate the value of shear wave velocity value (SWV) and shear wave velocity ratio (SWR) in differentiating between malignant and benign thyroid nodules using virtual touch tissue quantification (VTQ) of acoustic radiation force impulse (ARFI) technology. Methods: The SWV and SWR were analyzed in 155 thyroid nodules in 155 patients (93 benign and 62 malignant) and eighty normal thyroid glands. The diagnostic performance of SWV and SWR were compared. Results: The mean value of SWV of malignant nodules differed significantly from those of the benign nodules (6.34 +/- 2.58 m/s vs. 2.15 +/- 0.59 m/s, P<0.05) and the normal thyroid (1.96 +/- 0.31 m/s, P<0.05). There was no statistically significant difference between the mean value of SWV of benign nodules and normal thyroid (P>0.05). The mean value of SWR of malignant nodules differed significantly from those of the benign nodules (2.99 +/- 1.45 vs. 1.07 +/- 0.34, P<0.05). The sensitivity, specificity, positive predictive values, negative predictive values and accuracy of SWV in differentiating between malignant and benign nodules were 96.80%, 95.70%, 93.75%, 97.80% and 96.13% respectively based on the cutoff point as 2.84 m/s. Those of SWR were 91.90%, 81.70%, 77.03%, 93.83% and 85.83% based on the cutoff point as 1.32. The diagnostic accuracy rate of SWV was statistically higher than that of SWR (P<0.05). Conclusion: VTQ of ARFI technology provides the quantitative information of thyroid tissue elasticity and has high accuracy rate in differentiating between malignant and benign nodules. It is a useful complement for conventional ultrasonography. (C) 2013 Elsevier Ireland Ltd. All rights reserved.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2013]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2013]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Ultrasound Department, The Fourth Hospital of Hebei Medical University, No.12 Jiankang Road, Shijiazhuang 050011, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39770 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号