Development of a sample pretreatment device integrating ultrasonication, centrifugation and ultrafiltration, its application on rapid on-site screening of illegally added chemical components in heat-clearing, detoxicating Chinese patent medicines followed by electrospray ionization-ion mobility spectrometry.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]School of Pharmacy, Hebei Medical University, 361 East Zhongshan Road, Shijiazhuang, 050017, China. [2]Department of Pharmacy, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, China. [3]Department of Clinical Pharmacology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, China.
出处:
ISSN:

关键词: Sample pretreatmentDevice integrating ultrasonication Centrifugation and ultrafiltrationComplex sample matrixRapid on-site screeningIllegal additionESI-IMS

摘要:
In this paper, a simple and rapid sample pretreatment device integrating ultrasonication, centrifugation and ultrafiltration (UCU) was reported for preparation of trace analytes in complex matrices. The UCU device was composed of two parts, A and B. The sample and extraction solvent were put into Part B for ultrasonic extraction. Subsequently, Part A and Part B were integrated and sealed for centrifugation and ultrafiltration. Finally, the ultrafiltrate in Part A was taken out for subsequent detection. After optimization, the device was applied to rapid on-site screening of five illegally added chemical components in heat-clearing and detoxicating Chinese patent medicines by combining with electrospray ionization-ion mobility spectrometry (ESI-IMS). The method showed good performance in terms of linearity with correlation coefficients (R2) above 0.9976 and limits of detection (LODs) in the range of 0.049-0.391 μg mL-1. The recoveries were from 96.5 % to 100.8 %. The whole analysis process was within 11 min. The proposed method was further compared with other methods reported in the literature and the advantages and considerations were also explored. The results demonstrated that it was a simple, fast and accurate technique. The establishment of this method not only greatly improved the experimental efficiency but also avoided potential sample pollution brought by multiple sample transfer, and could provide a powerful means for rapid on-site analysis of trace analytes in complex matrices. Copyright © 2020 Elsevier B.V. All rights reserved.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 分析化学 3 区 药学
最新[2025]版:
大类 | 3 区 医学
小类 | 2 区 分析化学 3 区 药学
JCR分区:
出版当年[2021]版:
Q2 CHEMISTRY, ANALYTICAL Q3 PHARMACOLOGY & PHARMACY
最新[2024]版:
Q2 CHEMISTRY, ANALYTICAL Q2 PHARMACOLOGY & PHARMACY

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]School of Pharmacy, Hebei Medical University, 361 East Zhongshan Road, Shijiazhuang, 050017, China.
通讯作者:
通讯机构: [1]School of Pharmacy, Hebei Medical University, 361 East Zhongshan Road, Shijiazhuang, 050017, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号