A preliminary evaluation study of applying a deep learning image reconstruction algorithm in low-kilovolt scanning of upper abdomen.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China. [2]GE Company, Beijing, China.
出处:
ISSN:

摘要:
To investigate feasibility of applying deep learning image reconstruction (DLIR) algorithm in a low-kilovolt enhanced scan of the upper abdomen.A total of 64 patients (BMI<28) are selected for the enhanced upper abdomen scan and divided evenly into two groups. The tube voltages in Group A are 100kV in arterial phase and 80kV in venous phase, while tube voltages are 120kV during two phases in Group B. Image reconstruction algorithms used in Group A include the filtered back projection (FBP) algorithm, the adaptive statistical iterative reconstruction-Veo (ASIR-V 40% and 80%) algorithm, and the DLIR algorithm (DL-L, DL-M, DL-H). Image reconstruction algorithm used in Group B is ASIR-V40%. The different reconstruction algorithm images are used to measure the common hepatic artery, liver, renal cortex, erector spinae, and subcutaneous adipose in the arterial phase and the average CT value and standard deviation of the portal vein, liver, spleen, erector spinae, and subcutaneous adipose in the portal phase. The signal-to-noise ratio (SNR) is calculated, and the images are also scored subjectively.In Group A, noise in the aorta, liver, portal vein (the portal phase), spleen (the portal phase), renal cortex, retroperitoneal adipose, and muscle is significantly lower in both the DL-H and ASIR-V80% images, and the SNR is significantly higher than those in the remaining groups (P<0.05). The SNR of each tissue and organ in Group B is not significantly different from that in DL-M, DL-L, and ASIR-V40% in Group A (P>0.05). The subjective image quality scores in the DL-H and B groups are higher than those in the other groups, and the FBP group has significantly lower image quality than the remaining groups (P<0.05).For upper abdominal low-kilovolt enhanced scan data, the DLIR-H gear yields a more satisfactory image quality than the FBP and ASIR-V.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
JCR分区:
出版当年[2021]版:
Q3 INSTRUMENTS & INSTRUMENTATION Q3 OPTICS Q3 PHYSICS, APPLIED
最新[2023]版:
Q3 INSTRUMENTS & INSTRUMENTATION Q3 OPTICS Q3 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
通讯作者:
通讯机构: [1]Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China. [*1]Department of Radiology, The Fourth Hospital of Hebei Medical University, No. 12 of Jiankang Road, Chang’an District, Shijiazhuang 050011, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39804 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号