Demonstration of quasi-real-time intrafractional motion in esophageal cancer radiotherapy provided by ExacTrac X-ray snap verification.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin, China [2]Department of Radiotherapy, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China [3]Department of Radiation Oncology, Jining NO.1 People’s Hospital, Jining, China [4]Department of Radiotherapy, the Fourth Hospital of Hebei Medical University, Shijiazhuang, China [5]Department of Clinical Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
出处:
ISSN:

关键词: Quasi-real-time monitoring esophageal cancer ExacTrac X-ray Snap

摘要:
To investigate the following hypotheses: (1) ExacTrac X-ray Snap Verification (ET-SV) is an alternative to CBCT for positioning patients with esophageal carcinoma (EC), (2) ET-SV can detect displacement in EC patients during radiotherapy (RT) and (3) EC patients can be feasibly monitored in quasi-real-time with ET-SV during RT.Anthropomorphic phantoms and 13 patients were included in this study. CBCT and ET-SV were both implemented before treatment delivery to detect displacement, and their correction results were compared. For the patient tests, positional correction in 3 translational directions and the yaw direction were applied using the ET-SV correction results. The residual error was detected immediately using ET-SV. Finally, to acquire the intrafractional motion, ET-SV was implemented when the gantry was at 0°, 90°, 180° and 270°, respectively.In phantom tests, the maximum value of the difference in displacement between the CBCT and ET systems was 1.16 mm for translation and 0.31° for yaw. According to Bland-Altman analysis of the patient test results, 5% (5/98), 5% (5/98), 5% (5/98), and 4% (4/98) of points were beyond the upper and lower limits of agreement in the AP, SI, LR and yaw directions, respectively. The mean residual error was -0.482 mm, 1.215 mm, 1.0 mm, -0.487°, 0.105°, and 0.003° in the AP, SI, LR, pitch, roll and yaw directions, respectively. The intrafractional displacement ranged from -0.21 mm to 0 mm for translation and from -0.63° to 0.21° for rotation. The mean total translational error for intrafractional motion increased from 0.47 mm to 1.14 mm during the treatment.The accuracy of ET-SV for EC RT positional correction is comparable to that of CBCT. Thus, Quasi-real-time intrafractional monitoring can be used to detect EC patient displacement during radiotherapy.

语种:
WOS:
PubmedID:
中科院分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
JCR分区:
出版当年[2022]版:
Q2 INSTRUMENTS & INSTRUMENTATION Q2 OPTICS Q2 PHYSICS, APPLIED
最新[2024]版:
Q3 INSTRUMENTS & INSTRUMENTATION Q3 OPTICS Q4 PHYSICS, APPLIED

影响因子: 最新[2024版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin, China [2]Department of Radiotherapy, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
通讯作者:
通讯机构: [5]Department of Clinical Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China [*1]Department of Clinical Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan 250117, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号