Effect of storage time of paraffin sections on the expression of PD-L1 (SP142) in invasive breast cancer

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Med Univ, Dept Pathol, Hosp 4, 12 Jiankang Rd, Shijiazhuang 050011, Hebei, Peoples R China
出处:
ISSN:

关键词: Breast cancer PD-L1 Immunohistochemistry Paraffin sections Storage time

摘要:
BackgroundPD-L1 staining using long-stored paraffin sections may not be consistent with the true PD-L1 expression of patients. Therefore, it is necessary to explore the expression of PD-L1(SP142) in paraffin sections of invasive breast cancer with different storage times and the optimal storage temperature for unstained paraffin sections.MethodsThe study included 71 cases of PD-L1(SP142) positive breast cancer. The unstained paraffin sections were stored at room temperature conditions (20-25 degrees C), 4 degrees C, -20 degrees C and - 80 degrees C, respectively. PD-L1 staining was performed at 1, 2, 3, 4, 8, 12 and 24 weeks of storage. PD-L1 expression was assessed with a continuity score.ResultsThe PD-L1 antigen was gradually lost as the storage time of paraffin sections increased. The PD-L1 positivity rate was 97.18% at 1 week for the sections stored at room temperature, and decreased from 83.10 to 71.83% for the sections stored for 2 weeks to 4 weeks, and 61.97%, 54.93%, and 32.93% for 8, 12, and 24 weeks, respectively. When stored at low temperatures of 4 degrees C, -20 degrees C and - 80 degrees C, the positivity rate decreases with the same trend but more slowly compared to room temperature. The mean IC score of PD-L1 also showed a gradual decrease in all cases. In the consistency analysis, PD-L1 expression in slices stored at room temperature for 2 weeks was consistent with PD-L1 expression in fresh slices (ICC >= 0.9 for all slices), and PD-L1 expression in slices stored at 4 degrees C or -20 degrees C for 4 weeks was consistent with PD-L1 expression in fresh slices (ICC >= 0.9 for all slices). When stored under refrigeration at -80 degrees C, PD-L1 expression in slices stored for 3 weeks was consistent with that in fresh slices (ICC >= 0.9).ConclusionsTo our knowledge, this is the first article on the effect of preservation time and preservation temperature of paraffin sections on PD-L1 expression in breast cancer. Long-term storage of paraffin sections of unstained invasive breast cancer can lead to antigen loss of PD-L1 (SP142). Refrigerated storage of paraffin sections can delay antigen loss, with best results at 4 degrees C or -20 degrees C, and a storage time of no more than 4 weeks is recommended.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 病理学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 病理学
JCR分区:
出版当年[2023]版:
Q2 PATHOLOGY
最新[2024]版:
Q2 PATHOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版] 出版后一年[2024版]

第一作者:
第一作者机构: [1]Hebei Med Univ, Dept Pathol, Hosp 4, 12 Jiankang Rd, Shijiazhuang 050011, Hebei, Peoples R China
通讯作者:
通讯机构: [1]Hebei Med Univ, Dept Pathol, Hosp 4, 12 Jiankang Rd, Shijiazhuang 050011, Hebei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号