Image quality assessment and feasibility of three-dimensional amide proton transfer-weighted imaging for hepatocellular carcinoma

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]CT & MRI Department, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China. [2]Philips (China) Investment Co., Ltd., Beijing, China.
出处:
ISSN:

关键词: Three-dimensional amide proton transfer-weighted imaging (3D-APTw imaging) hepatocellular carcinoma (HCC) diagnostic feasibility image quality

摘要:
With the continuous innovation of magnetic resonance imaging (MRI) hardware and software technology, amide proton transfer-weighted (APTw) imaging has been applied in liver cancer. However, to our knowledge, no study has evaluated the feasibility of a three-dimensional amide proton transfer-weighted (3D-APTw) imaging sequence for hepatocellular carcinoma (HCC). This study thus aimed to conduct an image quality assessment of 3D-APTw for HCC and to explore its feasibility.3D-APTw MRI examinations were completed in 134 patients with clinically suspected HCC. According to the uniformity of APTw signal in the liver and within the lesion and the proportion of artifact and missing signal regions, APTw images were subjectively scored using a 5-point scale. The scanning success rate of liver APTw imaging was calculated as the ratio of the number of cases with a quality assurance measurement of more than 3 to the total number of HCC cases. The intra- and interobserver quality assurance measurements for APTw images were compared via the Kappa consistency test. Within the HCC cases with a minimum image quality threshold of 3 points, the APT values of HCC and the liver parenchyma, signal-to-noise ratio of APT-weighted images (SNRAPTw), and contrast-to-noise ratio of HCC (CNRHCC) were measured by two observers. The intra- and interobserver agreement was assessed using the intraclass correlation coefficient (ICC). The differences in APT values between HCC and liver parenchyma was determined using the Mann-Whitney test.Sixty-six HCC cases with a quality assurance measurement of APTw imaging were included in the final analysis, and the calculated success rate was 70.21% (66/94). The subjective APT image quality scores of the two observers were consistent (3.66±1.18, 3.50±1.19, and 3.68±1.18), and no intergroup or intragroup statistical differences were found (P=0.594, and P=0.091), but the consistency of inter- and intraobserver was not as satisfactory (κ=0.594 and κ=0.580). The APT values in HCC lesion were significantly higher than those in liver parenchyma (2.73%±0.91% vs. 1.62%±0.55%; P<0.001). The APT values in HCC showed favorable intra- and interobserver consistency between the two observers (ICC =0.808 and ICC =0.853); the APT values in liver parenchyma, SNRAPTw, and CNRHCC values had moderate intraobserver consistency (ICC =0.578, ICC =0.568, and ICC =0.508) and interobserver consistency (ICC =0.599, ICC =0.199, and ICC =0.650). The coefficients of variation of the APTw values in the HCC lesion and in liver parenchyma were 33.4% and 34.4%, respectively. The SNRAPTw and CNRHCC were 30.75±18.74 and 3.56±3.19, with a coefficient of variation of 60.9% and 74.9%, respectively.Liver 3D-APTw imaging was preliminarily demonstrated to be clinically feasible for evaluating HCC.2024 Quantitative Imaging in Medicine and Surgery. All rights reserved.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2024]版:
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2024版] 出版当年五年平均 出版前一年[2023版]

第一作者:
第一作者机构: [1]CT & MRI Department, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39770 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号