Feasibility analysis of non-electrocardiogram-triggered chest low-dose computed tomography using a kV-independent reconstruction algorithm for predicting cardiovascular disease risk in patients receiving maintenance hemodialysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Med Univ, Hosp 4, Dept Computed Tomog & Magnet Resonance, Shijiazhuang, Peoples R China [2]Hebei GEO Univ, Sch Math & Sci, Shijiazhuang, Peoples R China [3]Siemens Healthineers Ltd, CT Collaborat, Beijing, Peoples R China
出处:
ISSN:

关键词: Coronary artery disease Vascular calcification Risk factors Tomography Radiation dosage X-ray computed

摘要:
Objectives This study aimed to evaluate the feasibility and accuracy of non-electrocardiogram (ECG)-triggered chest low-dose computed tomography (LDCT) with a kV-independent reconstruction algorithm in assessing coronary artery calcification (CAC) degree and cardiovascular disease risk in patients receiving maintenance hemodialysis (MHD). Methods In total, 181 patients receiving MHD who needed chest CT and coronary artery calcium score (CACS) scannings sequentially underwent non-ECG-triggered, automated tube voltage selection, high-pitch chest LDCT with a kV-independent reconstruction algorithm and ECG-triggered standard CACS scannings. Then, the image quality, radiation doses, Agatston scores (ASs), and cardiac risk classifications of the two scans were compared. Results Of the 181 patients, 89, 83, and 9 were scanned at 100, 110, and 120 kV, respectively. Excluding those scanned at 120 kV, 172 patients were enrolled. Although the ASs of non-ECG-triggered LDCT were lower than those of the standard CACS, the agreement and correlation of ASs of the two scans were excellent, and both intraclass correlation coefficients (ICCs) and Pearson's correlation coefficients were > 0.96. Cardiac risk classifications did not significantly differ between the non-ECG-triggered LDCT and standard CACS (chi(2) = 3.933, P = 0.269), and the agreement was excellent (weighted kappa value = 0.936; 95% confidence interval (CI): 0.903-0.970). The effective radiation doses of standard CACS and non-ECG-triggered chest LDCT scannings were 1.34 +/- 0.74 and 1.04 +/- 0.35 mSv, respectively. Conclusions The non-ECG-triggered, automated tube voltage selection, high-pitch chest LDCT protocol with a kV-independent reconstruction algorithm can obtain chest scans and ASs simultaneously and significantly reduce patients' radiation exposure.

语种:
WOS:
PubmedID:
中科院分区:
出版当年[2025]版:
大类 | 3 区 医学
小类 | 4 区 心脏和心血管系统
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 心脏和心血管系统
JCR分区:
出版当年[2024]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2024]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2024版] 最新五年平均 出版当年[2025版] 出版当年五年平均 出版前一年[2024版]

第一作者:
第一作者机构: [1]Hebei Med Univ, Hosp 4, Dept Computed Tomog & Magnet Resonance, Shijiazhuang, Peoples R China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号