Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China [2]Department of Laboratory, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China [3]Department of Radiology, China ResourcesWuhan Iron and Steel General Hospital, Wuhan, China [4]Department of Radiology, Shanxi Cancer Hospital, Taiyuan, China [5]Department of Radiology, Edong Medical Group Central Hospital, Huangshi, China [6]GE Healthcare Life Science, Beijing, China [7]Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
出处:
ISSN:

关键词: Multicenter contrast agent tube voltage computed tomography chest

摘要:
To evaluate the influence of low-concentration contrast agents and low-tube-voltage computed tomography on chest enhancement examinations, we conducted a multicenter prospective study. A total of 216 inpatients enrolled from 12 different hospitals were randomly divided into four groups: A: voltage, 120 kVp; iohexol, 350 mgl/mL; B: voltage, 100 kVp, iohexol, 350 mgl/mL; C: voltage, 120 kVp, iodixanol, 270 mgl/mL; and D: voltage, 100 kVp, iodixanol, 270 mgl/mL. Subjective image quality was assessed by two radiologists and compared by weighted kappa test. The objective image scores, scanning radiation doses, and pathological coincidence rates were analyzed. There were no significant differences in gender, age, height, weight, and body mass index between the four groups (p > 0.05). The consistency of the radiologists' ratings were good, with kappa value ranging from 0.736 (95% confidence interval: 0.54-0.933) to 0.809 (95% confidence interval: 0.65-0.968), and there was no difference in subjective image score between the four groups. The computed tomography value of group D had no difference with group A. The volume computed tomography dose index, dose length product, and effective dose of group D (6.93 +/- 3.03, 241.55 +/- 104.75, and 3.38 +/- 1.47, respectively) were all significantly lower than those of group A (10.30 +/- 4.37, 359.70 +/- 152.65, and 5.04 +/- 2.14, respectively). There was no significant difference in the imaging diagnosis accuracy rate between the four groups (p > 0.05). The results indicated that low-concentration contrast agents (270 mgl/mL) and low-tube-voltage (100 kVp) computed tomography can not only decrease radiation dose but also guarantee the image quality and meet the needs of imaging diagnosis in chest enhancement examinations, which make it possible for its generalization and application.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2020]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
最新[2025]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
JCR分区:
出版当年[2020]版:
Q2 MULTIDISCIPLINARY SCIENCES
最新[2024]版:
Q2 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2024版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China
通讯作者:
通讯机构: [1]Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China [*1]Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Huanhuxi Road, Hexi District, Tianjin 300060, China. [*2]Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Huanhuxi Road, Hexi District, Tianjin 300060, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号