Quantification and comparison the dosimetric impact of two treatment couch model in VMAT

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Tianjin Univ, Dept Biomed Engn, Tianjin, Peoples R China [2]Hebei Med Univ, Dept Radiat Oncol, Hosp 4, Shijiazhuang, Hebei, Peoples R China [3]Hebei Gen Hosp, Dept Gastroenterol, Shijiazhuang, Hebei, Peoples R China
出处:
ISSN:

关键词: carbon fibre couch top couch model dose attenuation Monaco

摘要:
The use of Monte Carlo treatment planning systems (TPS) in radiation therapy has increased the dosimetric accuracy of VMAT treatment sequences. However, this accuracy is compromised by not including the treatment couch into the treatment planning process. Therefore, the impact of the treatment couch on radiation delivery output was determined, and two different couch models (uniform couch model A vs two components model B) were included and tested in the Monaco TPS to investigate which model can better quantify the couch influence on radiation dose. Relative attenuation measurements were performed following procedures outlined by TG-176 with three phantom positions for A-B direction: on the left half (L), in the center (C) and on the right half (R) of the couch. As well as absolute dose comparison of static fields of 10 9 10 cm(2) that were delivered through the couch tops with that calculated in the TPS with the couch model at 2 mm and 5 mm computing grid size respectively. The most severe percentage deviation was 4.60% for the phantom positioned at the left half of the couch with 5 mm grid size at gantry angle 120 degrees. The couch model was included in the TPS with a uniform ED of 0.26 g/cm(3) or a two component model with a fiber 0.52 g/cm(3) and foam core 0.1 g/cm(3). After including the treatment couch, the maximum mean dose attenuation was reduced from 3.68% without couch included to (0.60, 0.83, 0.72, and 1.02) % for model A and model B at 2 and 5 mm voxel grid size. The results obtained showed that Model A performed better than the model B, demonstrating lower deviations from measurements and better robustness against dose grid resolution changes. Considering the results of this study, we propose the systematic introduction of the couch Model A in clinical routine. All the reported findings are valid for the Elekta iBEAM (R) evo Extension 415 couch and these methods can also be used for other couch model.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2018]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Tianjin Univ, Dept Biomed Engn, Tianjin, Peoples R China [2]Hebei Med Univ, Dept Radiat Oncol, Hosp 4, Shijiazhuang, Hebei, Peoples R China
通讯作者:
通讯机构: [2]Hebei Med Univ, Dept Radiat Oncol, Hosp 4, Shijiazhuang, Hebei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42313 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号