高级检索
当前位置: 首页 > 详情页

Handling measures for the implantable vascular access device to prevent of catheter fracture/disruption

| 导出 |

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Hebei Med Univ, Dept Breast Ctr, Hosp 4, Shijiazhuang 050011, Peoples R China
出处:
ISSN:

关键词: Implantable vascular access device catheter fracture catheter disruption risk factors reasons handling measures

摘要:
This study aims to investigate the causes of catheter fracture and handling measures for implantable vascular access devices to prevent catheter fracture. We retrospectively examined 3088 adult patients with catheter fracture/disruption caused by totally implantable vascular access devices (TIVDs). In the 3088 cases, implantation was via the internal jugular vein in 2909 cases and the subclavian vein in 179 cases. Catheter fracture/disruption occurred in 13 patients (0.42%). In 7 cases in which implantation was via the internal jugular vein (left side, n = 4 and right side, n = 3), the incidence of catheter fracture/disruption was 0.24% (7/2909). Four patients had catheter fracture, and 3 patients had catheter disruption. Among those with subclavian venipuncture, 6 patients had catheter fracture/disruption, with an incidence rate of 3.35% (6/179), including 4 cases of implantation via the left side and 2 cases of implantation via the right side. The incidence of catheter fracture/disruption in the internal jugular venipuncture was significantly lower than that in the subclavian venipuncture (chi(2) = 38.938, P = 0.000). All of the cases of catheter fracture/rupture were treated safely, without any deaths in all the patient groups. Acutenes activity, body shape, improper operation, catheter material, and special anatomical structure are the causes of catheter fracture/disruption. Performing the appropriate surgical method and informing patients to avoid strenuous activities could reduce the incidence of catheter fracture/disruption.

语种:
被引次数:
WOS:
中科院分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2016]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2024]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2024版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Hebei Med Univ, Dept Breast Ctr, Hosp 4, Shijiazhuang 050011, Peoples R China
通讯作者:
通讯机构: [1]Hebei Med Univ, Dept Breast Ctr, Hosp 4, Shijiazhuang 050011, Peoples R China [*1]Department of Breast Center, Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42313 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号