机构:[1]Department of Interventional Radiology,The 4th Hospital of Hebei Medical University, Shijiazhuang 050011, China医技科室放射科河北医科大学第四医院[2]Department of General Surgery, The 4th Hospital of Hebei Medical University, Shijiazhuang 050011, China河北医科大学第四医院
Background: To investigate the risk factors of the in vivo implantable venous access port (IVAP) catheter fracture. Methods: We retrospectively analyzed 3,102 cases of patients with vascular access devices from November 2013 to March 2016 in the hospital by PACS. The clinical and radiographic features (age, occupation, living habit, IVAP duration, intravascular outer catheter angle, location of catheter tip and IVAP implantation site ) were summarized to analyze the related risk factors of fracture in the 3,102 patients. Results: There were 15 cases of fracture in 3,102 patients, and the fracture site were located at the entrance of the internal jugular vein (IJV) (n=12), the outlet of the vascular access devices (n=1), the distal portion of the catheter (n=2). Fracture was closely related to the factors of port time, age and occupation, but not related to the location of the port, the position of the catheter tip and the angle of the inner and the outer catheter. Age and IVAP duration were an independent risk factor for IVAP catheter fracture. Conclusions: Implantable vascular access devices are approved by its advantages of being safe, effective and less invasive. It is important to clarify the related factors and early prevention of fracture.
第一作者机构:[1]Department of Interventional Radiology,The 4th Hospital of Hebei Medical University, Shijiazhuang 050011, China
通讯作者:
通讯机构:[1]Department of Interventional Radiology,The 4th Hospital of Hebei Medical University, Shijiazhuang 050011, China[*1]Department of Interventional Radiology, The 4th Hospital of Hebei Medical University, No. 12 Health Road, Shijiazhuang 050011, China.
推荐引用方式(GB/T 7714):
Ai Ning,Li Li,Yin Fenghua,et al.Analysis of risk factors for implantable venous access port catheter fracture with internal jugular vein[J].ANNALS OF PALLIATIVE MEDICINE.2020,9(1):30-36.doi:10.21037/apm.2019.12.04.
APA:
Ai, Ning,Li, Li,Yin, Fenghua,Li, Zhigang,Geng, Cuizhi&Yang, Guang.(2020).Analysis of risk factors for implantable venous access port catheter fracture with internal jugular vein.ANNALS OF PALLIATIVE MEDICINE,9,(1)
MLA:
Ai, Ning,et al."Analysis of risk factors for implantable venous access port catheter fracture with internal jugular vein".ANNALS OF PALLIATIVE MEDICINE 9..1(2020):30-36