Application Value of Real-Time Shear Wave Elastography in Diagnosing the Depth of Infiltrating Muscular Layer of Endometrial Cancer.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Department of Gynecology and Obstetrics Ultrasound, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, China
出处:
ISSN:

关键词: ultrasound real-time shear wave elastography endometrial cancer infiltrating muscularis diagnostic value

摘要:
To explore the clinical value of real-time shear wave ultrasonic elastography in diagnosing the depth of infiltrating muscularis of endometrial cancer. Seventy-one patients with stage I endometrial cancer infiltrating the myometrium and 37 patients with normal physical examination were enrolled and divided into three groups: endometrial cancer superficial muscle infiltration group, endometrial cancer deep muscle infiltration group, and normal control group. After completing 2-dimensional ultrasound examination, each patient switched to the real-time shear wave elastography mode to measure the elasticity values Emax, Emean, and Esd. For control group, comparison of elastic modulus values between superficial muscular layer near the intimal surface and the deep muscular layer near the serosa surface showed no difference (P > 0.05). For endometrial cancer superficial muscular infiltration group, significant difference was found regarding the elastic modulus values of infiltrated muscular layer and uninfiltrated muscular layer (Emax and Emean) without difference for Esd (P > 0.05). A significant difference of elastic modulus was observed between control group and deep myometrial infiltration group (P < 0.05) without difference of Emean or Emax but with difference of Esd. The accuracy in diagnosing muscular layer infiltration was 78.9% for Emax cutoff and 82.5% for Emean cutoff. The rate of using Emax ≥32.22 kPa or Emean ≥27.54 kPa as the ultrasound standard for diagnosing myometrium infiltration was 92.9%. The accuracy for the diagnosis of muscular layer infiltration was 96.1% for Emax cutoff, 94.1% for Emean cutoff and 86.3% for Esd cutoff. Real-time shear wave elastography is helpful to determine the depth of infiltrating myometrium of endometrial cancer. © 2020 American Institute of Ultrasound in Medicine.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 3 区 声学 4 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2021]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q2 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Gynecology and Obstetrics Ultrasound, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, China
通讯作者:
通讯机构: [1]Department of Gynecology and Obstetrics Ultrasound, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, China [*1]Shijiazhuang, 12 Jian kang Road, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号