高级检索
当前位置: 首页 > 详情页

A fast and simple approach for the quantification of five anti-hypersensitivity drugs in saliva and urine by portable ion mobility spectrometry based on magnetic graphene oxide dispersive solid phase extraction

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province 050017, China [2]Department of Pharmacy, The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei Province 050011, China [3]Department of Clinical Pharmacology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei Province 050011, China
出处:
ISSN:

关键词: Ion mobility spectrometry Magnetic graphene oxide Anti-hypersensitivity drugs Saliva and urine Analysis Rapid in-situscreening

摘要:
Fatal road traffic crashes are often related to multifarious risk factors, among which driving under the influence of drugs (DUID) has been reported as a significantly contributing cause. The first worry about the side-effect of influencing driving drugs is central nervous system adverse reaction, and anti-hypersensitivity drugs are a class of drugs with such side effects meanwhile has been widely used for common allergic diseases thus posing a great challenge to road safety and demanding a rapid and efficient method to detect. In this work, a method based on magnetic graphene oxide dispersive solid phase extraction (MGO-D-SPE) combined with ion mobility spectrometry (IMS) was firstly introduced for simultaneous determination of ephedrine, pseudoephedrine, diphenhydramine, promethazine and terfenadine in saliva and urine matrices. The prepared MGO was characterized by Fourier transform infrared (FT-IR) spectroscopy and thermo gravimetric analysis (TGA). Various parameters affecting extraction efficiency as well as instrumental acquisition sensitivity were studied and optimized. Under the optimum experimental conditions, the method was fully validated and the results demonstrated that the proposed method exhibited some advantages, including a good linearity covering large concentration ranges of 51.0-3040 ng ml(-1) for five anti-hypersensitivity drugs, and good accuracy was also obtained with high precision (CV% < 5.0 %). LODs and LOQs were 10.2-50.4 ng mL(-1) and 30.6-101.3 ng mL(-1), respectively. Consequently, the MGO-D-SPE-IMS methodology succeeded in building a hitherto unexplored tool for quantifying anti-hypersensitivity drugs in saliva and urine matrices of interest in DUID research field. (C) 2020 Elsevier B.V. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 分析化学 3 区 药学
最新[2025]版:
大类 | 3 区 医学
小类 | 2 区 分析化学 3 区 药学
JCR分区:
出版当年[2020]版:
Q2 CHEMISTRY, ANALYTICAL Q2 PHARMACOLOGY & PHARMACY
最新[2024]版:
Q2 CHEMISTRY, ANALYTICAL Q2 PHARMACOLOGY & PHARMACY

影响因子: 最新[2024版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province 050017, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:42329 今日访问量:0 总访问量:1365 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号