高级检索
当前位置: 首页 > 详情页

Diagnostic performance of the Kaiser score in the evaluation of breast lesions on contrast-enhanced mammography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Med Univ, Hosp 4, Dept Radiol, Shijiazhuang 050011, Peoples R China [2]Hebei Med Univ, Hosp 4, Dept Pathol, Shijiazhuang 050011, Peoples R China
出处:
ISSN:

关键词: Mammography Breast Neoplasms Decision Trees ROC Curve Biopsy

摘要:
Objectives: We aimed to investigate whether the Kaiser score (KS) could improve the diagnostic performance of breast imaging reporting and data system (BI-RADS) in evaluating breast enhancing lesions on contrast-enhanced mammography (CEM).Methods: Three hundred fifty-nine patients with 375 lesions (231 malignant and 144 benign) were included in this retrospective study from April 2019 to December 2021.Two readers with different levels of experience in breast imaging were asked to give a BI-RADS assessment category according to the CEM BI-RADS and final score based on the KS. The diagnostic performance of all lesions, mass and non-mass enhancement (NME) were assessed by receiver operating characteristic (ROC) analysis, and the areas under the ROC curve (AUCs) were measured. The weighted kappa coefficients were calculated to investigate the interreader agreement.Results: The AUCs of the KS for all lesions were 0.915 (95 %CI: 0.884-0.947) and 0.876 (95 %CI: 0.838-0.914) for two readers. When mass and NME were evaluated separately, the AUCs of the KS for mass were higher than those for NME (p < 0.001). The AUCs of BI-RADS for all lesion diagnoses ranged between 0.821 (95 %CI: 0.778-0.864) and 0.842(95 %CI: 0.801-0.883) for two readers. The AUCs of the KS were higher than those of BI-RADS (p < 0.001, p = 0.016). There were no significant differences in the sensitivity between the KS (97.4 %) and BI-RADS (99.6 %) for all lesions (p = 0.130). The specificity of the KS was significantly higher than that of BI-RADS (p < 0.001). Compared with BI-RADS, the application of the KS could have potentially obviated 41.7 % to 47.9 % unnecessary biopsies in 144 benign lesions. Interreader agreement between the two readers of the KS was almost perfect (k = 0.883 [95 % CI: 0.842-0.924]).Conclusion: The use of the KS provided a high diagnostic performance in distinguishing malignant and benign breast lesions on CEM and outperformed BI-RADS. The application of the KS can downgrade up to 47.9% of unnecessary biopsies of benign breast lesions.

语种:
被引次数:
WOS:
PubmedID:
中科院分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2022]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Hebei Med Univ, Hosp 4, Dept Radiol, Shijiazhuang 050011, Peoples R China
通讯作者:
通讯机构: [1]Hebei Med Univ, Hosp 4, Dept Radiol, Shijiazhuang 050011, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39770 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号