Reproducibility study of intravoxel incoherent motion and apparent diffusion coefficient parameters in normal pancreas

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Med Univ, Hosp 4, Dept CT & MRI, 12 Jiankang Rd, Shijiazhuang 050000, Hebei, Peoples R China
出处:
ISSN:

关键词: Intravoxel incoherent motion Pancreas Image quality Consistency test

摘要:
BACKGROUND The consistency of pancreatic apparent diffusion coefficient (ADC) values and intravoxel incoherent motion (IVIM) parameter values across different magnetic resonance imaging (MRI) devices significantly impacts the patient's diagnosis and treatment. AIM To explore consistency in image quality, ADC values, and IVIM parameter values among different MRI devices in pancreatic examinations. METHODS This retrospective study was approved by the local ethics committee, and informed consent was obtained from all participants. In total, 22 healthy volunteers (10 males and 12 females) aged 24-61 years (mean, 28.9 +/- 2.3 years) underwent pancreatic diffusion-weighted imaging using 3.0T MRI equipment from three vendors. Two independent observers subjectively scored image quality and measured the pancreas's overall ADC values and signal-to-noise ratios (SNRs). Subsequently, regions of interest (ROIs) were delineated for the IVIM parameters (true diffusion coefficient, pseudo-diffusion coefficient, and perfusion fraction) using post-processing software. These ROIs were on the head, body, and tail of the pancrease. The subjective image ratings were assessed using the kappa consistency test. Intraclass correlation coefficients (ICCs) and mixed linear models were used to evaluate each device's quantitative parameter values. Finally, a pairwise analysis of IVIM parameter values across each device was performed using Bland-Altman plots. RESULTS The Kappa value for the subjective ratings of the different observers was 0.776 (P < 0.05). The ICC values for inter-observer and intra-observer agreements for the quantitative parameters were 0.803 [95% confidence interval (CI): 0.684-0.880] and 0.883 (95%CI: 0.760-0.945), respectively (P < 0.05). The ICCs for the SNR between different devices was comparable (P > 0.05), and the ICCs for the ADC values from different devices were 0.870, 0.707, and 0.808, respectively (P < 0.05). Notably, only a few statistically significant inter-device agreements were observed for different IVIM parameters, and among those, the ICC values were generally low. The mixed linear model results indicated differences (P < 0.05) in the f-value for the pancreas head, D-value for the pancreas body, and D-value for the pancreas tail obtained using different MRI machines. The Bland-Altman plots showed significant variability at some data points. CONCLUSION ADC values are consistent among different devices, but the IVIM parameters' repeatability is moderate. Therefore, the variability in the IVIM parameter values may be associated with using different MRI machines. Thus, caution should be exercised when using IVIM parameter values to assess the pancreas.

基金:
语种:
WOS:
PubmedID:
中科院分区:
出版当年[2025]版:
大类 | 4 区 医学
小类 | 4 区 胃肠肝病学 4 区 外科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 胃肠肝病学 4 区 外科
JCR分区:
出版当年[2024]版:
最新[2023]版:
Q2 SURGERY Q3 GASTROENTEROLOGY & HEPATOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2024版] 出版当年五年平均 出版前一年[2023版]

第一作者:
第一作者机构: [1]Hebei Med Univ, Hosp 4, Dept CT & MRI, 12 Jiankang Rd, Shijiazhuang 050000, Hebei, Peoples R China
通讯作者:
通讯机构: [1]Hebei Med Univ, Hosp 4, Dept CT & MRI, 12 Jiankang Rd, Shijiazhuang 050000, Hebei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:39770 今日访问量:0 总访问量:1333 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北医科大学第四医院 技术支持:重庆聚合科技有限公司 地址:河北省石家庄市健康路12号